Digital Differential Thermometer and Probes
![]() |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The serviceman today needs an instrument that is reliable,
durable and accurate, has usable functions and probes for measuring
refrigeration and air-conditioning systems, and is reasonably priced. The Weiss
DT51A and DT52A offer such a product for temperature measurement.
The DT51A-1 is a type K thermocouple based single probe thermometer with
a range of -50/1999°F, resolution switch (0.1°F or 1°F), Data
Hold feature, Max Memory, °F or °C switch, and includes a general use
probe.
The DT52A-4 is alsotype K thermocouple with two probe inputs that offer
the differential feature required in refrigeration and air-conditioning
service. Includes two velcro probes with the sensor built in, plus a bead probe
and general probe with handle in an ABS carrying case.
Temperature indication follows National Bureau of Standards and IEC58
temperature/voltage tables for type K thermocouples which are supplied with the
thermometer.
| SPECIFICATIONS | GENERAL | |||||||||
| ELECTRICAL | Weight: 206 GM (7.2OZ) Dimension: 5.31"L x 2.83"W x 1.22"H (135x72x31mm) Battery: Standard 9V battery (NEDA 1604,6F22, or 006P) Battery Life: Approx. 150 hours Over range indication: OL Measurement rate: 2.5 measurements per second Display: (3) 1/2" digit liquid crystal display, 14mm high LCD Yellow Grip Sleeve: Included Data Hold Feature - Max Hold Feature Output Jack: For temperature recording or computer interface Instruction manual: included |
|||||||||
| Measurement Range: -50 to 1999°F
Resolution: 0.1° or 1° Maximum Voltage at thermocouple Input: 60V DC, 24 V AC RF Field Derating: Strong RF fields can adversely affect measurement accuracy |
||||||||||
| ENVIRONMENTAL | ||||||||||
| Ambient Operating Range: 0 to
50°C 32 to 122°F Storage Temperature: -10 to 60°C -14 to 140°F Humidty: 0% to 90% (0 to 35°C) 0% to 70% (35 to 50°C) |
||||||||||
| ACCURACY | ||||||||||
| For single-thermocouple measurements. For T1-T2 Measurements accuracy is ±(.0.3% of T1-T2 reading +2°C) | ||||||||||
| ±(.0.3% of T1-T2 reading +3°F) | ||||||||||
|
||||||||||
Ammonia
| Compact Thermo/ Hygrometer
| Digital Differential Thermometers
| Digital Vari-angle Thermometer
|
General Purpose Thermometers | HVAC Gauges | NSF Dial Thermometers | Refrigeration & Freezer Controls
Refrigeration & Freezer Thermometers
| Refrigeration Pressure Gauges
| Remote Reading Digital
Thermometers | Temperature
Humidity Tester
Thermo-Anemometer | Trade Line Gauges | Trade Line Thermometers | Tri-o-meters | Union Connected Dial Thermometers